Note: Only service technicians that are qualified to work on beverage, electric and pneumatic
equipment are permitted to perform the installation, maintenance, and repairs.
Store the Nitrogenator in a dry and climate controlled (40-95°F) room.
Always keep the Nitrogenator in an upright position / or in box as shipped.
Do not connect the AC power cable until this manual has been read completely and all connections are made as stated within.
Keep all gas lines dry so moisture does not enter the generator upon hookup.
Never place/stack objects on top of the Nitrogenator.
The Nitrogenator can be placed on the floor, a shelf, or mounted to a wall. It is recommended that the Nitrogenator be mounted to a weight-bearing wall that can support its weight as specified in the Specifications section. If placed on the floor, it should still be fastened in place so that it cannot move due to vibration or be damaged from falling over. It is mandatory that the leg or caster set be used if the system is placed on the floor. The Nitrogenator should be installed indoors, in an environment between 40° and 95° F, in the upright position where it will not be damaged by water or moving equipment. Leave at least 1” of clearance on
the back, bottom, and right sides. Ensure no other equipment will be exhausting heat directly into the air inlets on the right and bottom sides.
There is a 1⁄4” OD barb drain port on the bottom right side of the cabinet. This can be plumbed to the nearest drain on site.
Ensure that the unit is installed within a well-ventilated room – one that is not sealed off from normal living space air changes.
Warning: installation of the Nitrogenator EZ-2 in a non-ventilated room can result in asphyxiation.
The Nitrogenator can be placed on the floor, a shelf, or mounted to a wall. If placing on a floor or shelf,
the Nitrogenator should still be fastened in place so that it cannot move or fall over. The included legs or optional casters must be used if the Nitrogenator is not being mounted to a wall.
It is recommended that the Nitrogenator be mounted to a load-bearing wall that can support its weight
as listed in the Specifications section. If the wall studs are not 16” center to center, or you have the need
to reinforce the mounting area, it is recommended that at least 1⁄2“ thick plywood be installed prior to
mounting.
The Nitrogenator comes with a French Cleat Bracket wall mounting system. If mounting the system to a wall, this mount should be utilized. The French Cleat mounting system has pre-drilled holes for a standard 16” wall stud width.
See mounting diagrams below for instruction on how to properly mount using French Cleat Brackets.
Note: Use best general practices to ensure that the wood and system will be secure at its full weight.
Note: The Nitrogenator will vibrate during operation. Do not mount to a wall with other fixtures that
could be damaged or fall due to vibration. Amongst other variables, please keep in mind the vibration
and sound output when choosing mounting location.